Measurement and hence Testing, Commissioning & Maintenance made easy for E & I Engineers and Technicians with the latest technologies and quality products from Japan.
Please find below a must keep measuring instrument to make your plant electrical & Instrument maintenance easy.
Sr No | Equipment | Suitable Model Number | Required for | Key Features |
---|---|---|---|---|
1 | Non-Contact voltage detector for Electrician / Technician / Front Line Engineers | KEW 5711 | To safeguard Accidental live contact during Field work | Operating Voltage : AC 90-1000 V (Lo sensitivity – Helps to recognize phase from neutral in sockets) / AC 20-1000 V (Hi sensitivity – Checking the presence of voltage from a distance) |
2 | Wristwatch type hotline Proximity Alarm | HXW – 6WL HXW – 6W | To safeguard Accidental live contact during working in HT / LT Panels | HXW – 6WL : Hotline proximity detector wrist alarm, working voltage range : 400 V to 22 kV HXW – 6W : Hotline proximity detector wrist alarm, working voltage range : 1 kV to 42 kV |
3 | LV voltage detector for Checking Voltages in Control Panels | HTE 700D/DL | To safeguard Accidental live contact during working in HT / LT control Panels where there is presence of both AC and DC | AC and DC Low voltage detector, working voltage range AC : 50 V to 600 V, DC : 12 V to 750 V |
4 | • Power / Distribution / Lighting / VFD Transformer • HT / LT Motor • HT / LT Cables • HT / LT Panels • Alternators | 3025A - Insulation Tester | For IR & PI Measurement Suitable for Lighting / VFD Transformer, 415 V / 690 V / 3.3 kV Motors, Cables from 415 V to 3.3 kV, | • Measurement upto 100 GΩ • Automatic PI & DAR Measurement • 4 Voltage Range 250/500/1000/2500V |
3125A - Insulation Tester | For IR & PI Measurement Suitable for Power / Distribution Transformer, 6.6 / 11 kV Motors, Cables from 6.6 kV to 33 kV | • Measurement upto 1000 GΩ • Automatic PI & DAR Measurement • 5 Voltage Range 250/500/1000/2500/5000V |
||
5 | Any Equipment from 33 kV and Above Voltage level | 3128 - Insulation Tester | For Power Transformer, 33 kV & above Cables, HT Panels, Breakers, CT, PT, LA Any plants have equipment from 33 kV and above can keep this | • Measurement upto 35 TΩ • Automatic PI, DAR, DD & SV Measurement • Graphic representation of the IR and leakage current versus time on large display with bar graph and backlight. • Voltage Range 250/500/1000/2500/5000/10000/12000V |
6 | HT / LT Panels | 1020R - Digital Multimeter | For measuring continuity, resistance , AC / DC Voltages in Panels, Capacitance in APFC and Electrical Circuits | • DC V / DC mV / AC V / AC mV • Continuity Buzzer and Diode check • Capacitance and Frequency measurement • Resistance measurement upto 40.00MΩ |
1011 / 1012 - Digital Multimeter | For measuring continuity, resistance , AC / DC Voltages or Temperature in Panels, Capacitance in APFC and Electrical Circuits | • DC V / AC V / DC Amp / AC Amp • Continuity Buzzer and Diode check • Capacitance and Frequency measurement • Resistance measurement upto 60.00MΩ • 1011 is Digital Multimeter with Temperature Probe which can measure -50 to 300 DegC with use of temperature probe 8216 (Optional) • 1012 is Digital Multimeter with True RMS measurement |
||
1052 - Digital Multimeter | For measuring continuity, resistance , AC / DC Voltages or Temperature in Panels, Capacitance in APFC and Electrical Circuits | • DC V / AC V (RMS) / AC V (Mean)/ DC Amp / AC Amp • Continuity Buzzer and Diode check • Capacitance and Frequency measurement • Temperature measurement of -50 to 600 DegC with use of with the use of K-type Temperature probe (Optional) • Terminal shutter to prevent incorrect test leads' insertion in current terminals • Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H), Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), LCD backlight |
||
KEWMATE 2000A - Digital Multimeter with AC/DC Clamp Sensor | For measuring continuity, AC / DC Voltages, AC / DC amp upto 60 Amps, Frequency in Panels | • DC V / AC V / DC Amp / AC Amp • Continuity Buzzer and Frequency measurement • Resistance measurement upto 34.00MΩ • KM2000A is Digital Multimeter with Open AC/DC Clamp Sensor |
||
KEWMATE 2000A - Digital Multimeter with AC/DC Clamp Sensor | For measuring continuity, AC / DC Voltages, AC / DC amp upto 60 Amps, Frequency in Panels | • DC V / AC V / DC Amp / AC Amp • Continuity Buzzer and Frequency measurement • Resistance measurement upto 34.00MΩ • KM2000A is Digital Multimeter with Open AC/DC Clamp Sensor |
||
2002R - AC Digital Clamp Meters | For measuring Currents and Voltages in panels | • Can measure large AC current up to 2000A. • True RMS Feature • AC V upto 750 V, DC V upto 1000 V • Conductor Size - Ø55mm max. • Continuity buzzer sounds below 50±35Ω • Resistance measurement 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ (Auto-ranging) |
||
KEW 2007R - AC Digital Clamp Meters | For measuring Currents and Voltages in panels | • AC A - 600.0/1000A (Auto-ranging) • DC V / AC V upto 600 V • Conductor Size - φ33mm max. • Continuity buzzer sounds below 50±35Ω |
||
KEW 2200R - AC Digital Clamp Meters | For measuring Currents and Voltages in panels | • Ultra Slim and lightweight Handy design • 1000A AC Clamp Meter AC40/400/1000A Auto Range • True RMS Feature • DC V / AC V upto 600 V • Conductor Size - φ33mm max. • Continuity buzzer sounds below 90Ω • Resistance measurement 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ (Auto-ranging) |
||
2431 - Leakage Clamp Meter | For measuring small magnitude of current from mA to few Amp | • Three AC current ranges 20mA/200mA/200A. • Frequency Selector Switch to eliminate the effect of harmonics. • Measures from 0.01 mA to 199.9 A AC • Auto Power off function |
||
7 | ELCB / RCCB | 5406A - RCD Tester | For ELCB / RCCB Checking & Testing | • For 1 Phase RCCB / ELCB • For 15/30/50//100/200/500 mA ELCB / RCCB • Trip Current Duration : 1000 ms, 200 ms (×5) • 3 Leds for checking correct wiring status • Fault Condition Settings : × 1/2, × 1, × 5, × DC, Auto Ramp |
5410 - RCD Tester | For ELCB / RCCB Checking & Testing | • For 1 / 3 Phase RCCB / ELCB • For 10/20/30/200/300/500 mA ELCB / RCCB • Measuring range : 80V~450V 50/60Hz • Testing time 0ms~200ms • 3 Leds for checking correct wiring status • Fault Condition Settings : × 1/2, × 1, × 5, × DC, Auto Ramp • With Backlight & Sleep mode function |
||
8 | Earth Pit Resistance | 4105DL / 4105D-H – Digital Earth Tester | Earth resistance Measurement | • 3 Pole and 2 Pole Earth resistance Measurement (0.01 Ω to 2000 Ω) • Earth Voltage measurement (AC/DC 0 – 300 V) |
9 | Instrument | 2500 /2510 - Digital DC mA Clamp Meter | 4 to 20 mA measurement for various instruments | • 0.01mA resolution for DC current • Top class measurement 0.2% accuracy • Ø6mm clamp jaw easy to use in tight places • Measurement from 0.01mA to 120.0mA • Dual display with backlight shows both mA measurement and percent of 4-20 mA span |
10 | Power System | 6305 - Power Meter | For Measuring 3 phase Voltage, Current, PF, Power at HT/ LT Panels A Must keep for Plant having captive consumption of 5 MW | • Parameters : Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Power factor (cos θ), Neutral current • Measurements : Voltage, Current, Frequency, Active power • Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems • Power and Energy analysis (Active, Apparent and Reactive power) • Active power accuracy: ±0.3%rdg±0.2%f.s. • Wide selection of clamp sensors allows measurements from 0.1A to 3000A and many more features |
6315 – Power Quality Analyzer | For Simultaneous Power & Power quality measurements • Power/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch) A Must keep for Plant having captive consumption of 15 MW | • Measurement & Parameters : Voltage, Current, Frequency, Active power, Reactive power, Apparent power, Active energy, Reactive energy, Apparent energy, Power factor (cos θ), Neutral current, Demand, Harmonics, Quality (Swell /Dip /Interruption, Transients /Over voltage, Inrush current, Unbalance rate), Capacitance calculation for PF correction unit, Flicker • Wide selection of clamp sensors allows measurements from 0.1A to 3000A and many more features |
We, as an Electrical asset consultant and service provider always suggest what is best to run your industries smoothly and without hiccups of maloperation and breakdown.
And if you are looking for a dedicated agency that understands the direct link between your assets and your revenue, call/write to us, we will be happy to assist you.