Services
Relay Testing, Commissioning, & Programming
- Pre-Commissioning Commissioning
- Commissioning
- Programming & Configuration
- Relay of all types and makes
Circuit Breaker Servicing, Maintenance & Repairing
- Circuit Breaker of all types & makes
- SF6 | VCB|ACB
- From 415 V to 220 KV
Repairing & Retrofitting Solution
- Relays and Circuit Breakers of all types and makes
Switchyard Testing & Maintenance
- Switchyard Equipments like LA, CT, PT, Isolator, CB, Transformer etc. upto 220 KV
Diagnostic Testing
- Diagnostic Testing of HT Cables, Transformers, CTs, Motors, Generators, etc., preventive health check-up for panels and switchgears including Thermography and Partial Discharge
Transformer Testing, Scheme Checking & rectification
- Power Transformer
- Distribution Transformer Protection Scheme Testing (Differential, REF & SEF)
Power System Studies
- Power System Analysis, Load Flow Studies, Short Circuit Studies and Relay Coordination Studies, Transient Analysis, Arc Flash Analysis, Power Quality/Harmonic Analysis, etc
Supply & Trading
- Relay
- Circuit Breaker
- Spares of Switchgears
- Testing & Measuring Instruments
- PPES
Tailor-made Training Programs
- Switchgear & Protection
- Relaying & Protection
- Power System Studies & Relay Coordination
- Maintenance Practices
- Audit of Electrical Systems
Clients
Industries
Countries
Years of Trust
Clientele
Oil & Gas
Cement
Chemicals & Fertilizers
FMCG & Others
Steel
Power Utilities
EPC
Case Studies
How we saved a Process Plant from a breakdown
– System Protection was appointed to carry out the routine maintenance and testing of the Switchgears, Relays, CTs & PTs in one of the cement plants in India, having its own power plant, which combined with the grid supply catered to the plant load.
– Usually, at generating stations, we have TIE Feeders which connects Generator and Grid to maintain availability of Power. It is THE most important Feeder of any Plant, any problem in this can cause the entire plant black-out.
– Mostly, we employ a state-of-the-art CT Testing Instrument, CT Analyzer of Omicron Make, which uses IEC 61869-2 standard and performs model-based testing which is far more accurate and conclusive.
– During this Testing, Protection Core (5P10) of a CT was having a very high secondary resistance, the instrument displayed “Secondary Winding resistance is too high”. CT Analyzer determines winding resistance by applying DC current into Secondary winding and checks voltage drop across Secondary Terminals